Dongguan Chenglue Electronic co.,Ltd

Dongguan Chenglue Electronic co.,Ltd

Manufacturer from China
Verified Supplier
3 Years
Home / Products / X2 Safety Capacitor /

Anti Interference X2 Safety Capacitor 0.015 UF with Self Healing Property

Contact Now
Dongguan Chenglue Electronic co.,Ltd
Visit Website
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MrHe
Contact Now

Anti Interference X2 Safety Capacitor 0.015 UF with Self Healing Property

Ask Latest Price
Brand Name :CG
Model Number :X2 Safety Capacitor
Certification :VDE,CQC
Place of Origin :Dong Guan
MOQ :10000 Pieces
Price :Discuss
Payment Terms :T/T
Supply Ability :100000000 Pieces
Delivery Time :15-21 work days
Packaging Details :200pcs/ bag,carton size:45cm*31cm*34cm,inner box:29.2cm*21cm*31.3cm,a carton inside two inner boxs , 4000pcs/ box
Type :X2 Safety Capacitor
Capacitance :0.015UF
Rated Voltage :250-310V
Model Number: :MKP X2
Operating Temperature :-40℃~+110℃
Application :Widely Used In Across-the-line,interference Suprression Circuit,motor, Fan, Air Conditioner Etc.
Capacitance Tolerance :±10%(K)
Package :Carton sealing
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

0.015uf 310v X2 Safety Capacitor Anti-Interference Capacitor Self-Healing Property​

The full name of X capacitor is generally called: X2 (X1/X3/MKP) capacitor for suppressing power supply electromagnetic interference. Generally, the main functions in the circuit are: power supply cross-line circuit, EMI filtering, spark elimination circuit, etc. to ensure that the finished electronic products meet the EMC requirements.

Products Introduction

MPX are winded with metallized polypropylene film dielectric,Non-inductive construction, tinned copper wire leads,and flame retardant epoxy resin coating. They have excellent features of self-healing and good flame retardant according to UL 94-V0

Type application

The Products Would widely used for the Interference suppressors and across-the-line capacitor applications.Suitable for used in situations where failure of the capacitor will not lead to danger of electric shock.

Features

1 Non-induction construction

2 High moisture-resistance

3 Self-healing property

4 Flame retardant type(compliance with UL 94V-0)

5 Very small loss

6 Excellent frequency and temperature characteristics

7 High insulation resistance

Specifications(IEC 60384-14)

Test items Performance requirements Conditions of test
Capacitance Within the tolerance specified 1KHz, 1Vrms Max. at 25℃
Dissipation Factor 0.001 (0.1%) Max. 1KHz, 1Vrms Max. at 25℃
Voltage proof Shall be no abnormality Between terminals 4.3UR (Vdc) Test of 60sec.
Between terminal and enclosure UR×200%+1500Vac, 60sec.
Insulation resistance CR ≤ 0.33μF IR ≥ 15,000MΩ CR >0.33μF IR ≥6,000s 100±15Vdc, 60sec / 25℃
Robustness of terminations No wire breakage and no damage of capacitor

Tense Strength of Terminal Load Force : 1.0 Kg

Holding Time : 10 ± 1sec

Bending Strength of Terminal Load Force : 0.5 Kg

Bending Time : 4 x 90 ゚

Resistance to soldering heat

(1) Appearance : No visible damage

(2) △C/C : ≤ ±5% of the initial value

Solder temperature: 260±5℃

Solder time: 5±0.5sec

Solderability 95% of the surface tinning

Solder temperature: 260±5℃

Solder time: 2±0.5sec

Rapid change of temperature The capacitors shall be visually examined and there shall be no visible damage.

Lower category temperature: -40℃

Upper category temperature: 110℃

Number of cycles: 5

Duration t1 = 30 min

Vibration The capacitors shall be visually examined and there shall be no visible damage

Frequency range: 10~55Hz

Course: X,Y,Z (axis)

2h / axis ( 6h in total)

Displacement amplitude: 0.75mm

Test items Performance requirements Conditions of test
Climatic sequence

(1) Appearance : No visible damage

(2) △C/C : ≤ ±5% of the initial value

(3) DF ( tanδ) : ≤ 0.008 of increased value

(4) IR : ≥ 50% of the applicable limits

(5) Voltage proof : Normal

Dry Heat

Upper Temperature: 110℃

Lower Duration: 16Hrs

Cold

Temperature: -40℃

Duration: 2Hrs

Damp Heat Steady State

(1) Appearance : No visible damage

(2) △C/C : ≤ ±5% of the Initial value

(3) DF ( tanδ) : ≤ 0.008 of increased value

(4) IR : ≥ 50% of the applicable limits

(5) Voltage proof : Normal

+40°C and 93% RH, 56 days
Charge and discharge

(1) Appearance : No visible damage

(2) △C/C : ≤ ±10% of the initial value

(3) DF ( tanδ) : ≤ 0.008 of increased value

(4) IR : ≥ 50% of the applicable limits

Test voltage : √2 x URVAC 50 Hz

Charge and discharge: 0.5sec/time

Repeated for 10000 cycles

Endurance

(1) Appearance : No Visible Damage

(2) △C/C : ≤ ±10% of the initial value

(3) DF ( tanδ) : ≤ 0.008 of increased value

(4) IR : ≥ 50% of the applicable limits

1.25 x UR VAC 50 Hz, once every hour

increase to 1,000VAC for 0.1 second,

1,000 hours at upper rated temperature

Inquiry Cart 0